| 基本功能 |
| 8个量程: | | | 0.3-1-3-10-30-100-300-1000V Upeak = 2倍量程 |
|
| 输入阻抗: | |
| CMR共模抑制: | |
|
| 电流 |
| 6个量程: | | | 60-200 mA- 0.6 - 2-6 -20 A Ipeak = 2倍量程;正弦波时的zui大电平为150%(误差限值同100%) |
|
| 使用内部集成分流器时的输入阻抗 |
| 量程60、200 mA: | |
| 量程0.6、2 A: | |
| 量程 6、20 A: | |
| 电流过载: | | | zui大 25 A 连续 | | | 30 A < 5 s / 15 s,空载 | | | 100 A < 0.1 s / 30 s,空载 |
|
| 外部分流器或探头输入 |
| BNC端子: | | | 100 kW / 30 pF 30-100 mV-0.3-1-3-10 V |
|
| 过载: | |
| CMR共模抑制比: | |
| 基本准确度PP35 |
| 误差总限值 | |
| 量程 | |
| 读数 | |
| 输入电平 |
| | |
| % | |
| 100 | |
| 50 | |
| 30 | |
| 10 | |
| 5 | |
| 3 | |
| 1 | |
| |
| | |
| -3dB带宽 | |
| 频率 |
| | |
| [Hz] | |
| 0 | |
| 10 | |
| 45 | |
| 65 | |
| 500 | |
| 1000 | |
| 2000 | |
| 5000 | |
| 10000 | |
| 20000 | |
| 50000 | |
| 100000 | |
| PP35 |
| | | U 和 IBNC 之间 | U 和 IShunt 之间 |
|
| 角误差 | | 0.005°+0.005°/kHz | 0.025°+0.015°/kHz, 关闭抗混 叠滤波器 |
|
| 频率,Hz |
| | |
| 45 | |
| 64 | |
| 订购编号 |
| | |
| 3024677 | |
| 3024689 | |
| 3024886 | | | 10 A 同轴三芯分流器,含电缆(0.333 W,0~0.5 MHz) |
|
| 3024899 | | | 30 A 同轴三芯分流器,含电缆(0.010 W,0~0.5 MHz) |
|
| 3024847 | | | 100 A分流器,含电缆(0.001 W,0~0.5 MHz) |
|
| 3024858 | | | 150 A分流器,含电缆(0.5 mW,0~0.5 MHz) |
|
| 3024864 | | | 300 A分流器,含电缆(0.1 mW,0~1 MHz) |
|
| 3024873 | | | 500 A分流器,含电缆(0.1 mW,0~0.2 MHz) |
|
| 3024692 | | | LG分流器电缆,用于大电流分流器所有附件均提供2年质保。 |
|
| |
| | | 订货号 | 功率模块类型PP35 | 数量 | IEEE 488/LAN | 处理接口 |
|
| FLUKE-N4K 1PP35 1 PH N4K POWER ANALYZER W/35 | |
| FLUKE-N4K 3PP35 3 PH N4K POWER ANALYZER W/35 | |
| FLUKE-N4K 3PP35I 3 PH N4K POWER ANALYZER W/35/IFC2 | |
| 类型 |
| | |
| NORMA MEAS CABLES | | 3024661 | 测试线缆一套(包括电压测试线和电流测试线各2根) |
|
| FLUKE-N4K RACK KIT | |
| NORMA STAR POINT | | 3024704 | 外部星点适配器,可用于没有中点的测试场合 |
|